TBSVPT - BASO Gas Safety Pilot Valve and Thermocouple
This Baso Safety Valve offers 100% shut off of both the pilot and the main gas burner if the pilot light is extinguished or not sufficiently combusting. It is thermocouple operated and does not require electricity to operate.
This unit comes with the pilot light with 6' of ¼” aluminum gas tubing and a 6’ long thermocouple. It can be used with low pressure propane or natural gas, 0.5 psi maximum. Single-button operation to light the pilot. An external shut-off valve is required before the gas inlet in order to manually shut off the gas while the unit is in operation. The inlet and outlet of the valve are ¾” F NPT.
There are two outlets for pilot lights which could be used simultaneously. However, there is only one port for a thermocouple. If the pilot light without the thermocouple were to go out; gas would continue to pass through the safety valve.
Maximum btu/hr output for Natural Gas is 402,000 btu/hr.
Wt. 2#. Free shipping to the 48 contiguous U.S. States.